Shunt |
|
| Article | Description |

|
LK Valve actuator
LK Valve actuator for LK Shunt is used with other control equipment other than LK Control.
• LK Valve actuator 230V SSY319, used with LK Manifold shunt VS and CS, LK Shunt 2/3-2,5, 4,0, 6,3 plus LK Shunt UHP –6,3 and 10,0. • LK Valve actuator 0-10V SSB61, used with LK Manifold shunt, LK Shunt 2/3-2,5, 4,0, and to LK Shunt UHP –6,3 and 10,0. • LK Valve actuator 0-10V SQS65SL, used with LK Shunt 2/3-6,3. • LK Valve actuator SSA61/AV53, used with LK Manifold Shunt Compact 2-2,3/3,2 plus 2-1,2/1,6
|
Article no.
|
Voltage
|
Type
|
Unit
|
| 241 81 38 |
230V |
SSY319 |
pcs |
| 241 81 39 |
0-10V |
SSB61 |
pcs |
| 241 81 40 |
0-10V |
SQS65SL |
pcs |
| 241 81 41 |
0-10V |
SSA61/AV53 |
pcs |
|

|
LK Minishunt M60
Thermostat controlled shunt unit for use when smaller underfloor heating systems are to be connected to an existing heating system (approx 30m2 by 100W/m2). • Circulation pump Grundfos UPS 15-40ES 1 phase 230V AC 50 Hz max 60W 0,26A • Can be connected to series or parallel radiator systems • Thermostat with room temp. sensor length 2m • Temperature limiter of feed temperature • VF valve • Air bleed valve with hose nipple • The shunt can be assembled in both right and left operation • Bracket
• Accessories: LK Coupling with ½” male thread for one underfloor heating loop in PE-X dim 12, 16 or 20 mm. LK Mini Manifold for 2-4 underfloor heating loops in PE-X dim 12, 16 or 20 mm. LK Thermostat with room temp. sensor L= 5 m. LK Electronic Room Regulation (also available in a wireless design). LK Cabinet.
|
Article no.
|
WxHxD
|
c/c pipe prim/sek
|
Conn prim/sek
|
Weight
|
Unit
|
| 241 80 85 |
361x187x129 |
50/99 |
Cu15,3/4" m / 1/2" fm |
6.2 |
pcs |
|

|
LK Thermostatic head M60
LK Thermostatic head with 5 m capillary room sensor intended to LK Minishunt M60.
|
Article no.
|
Length
|
Unit
|
| 241 80 88 |
5 m |
pcs |
|

 |
LK Maniold Shunt VS
Complete pre- manufactured shunt unit with two way control valve. The shunt unit is to be used in systems with main pump in the primary circuit. • Grundfos variable speed circulation pump Alpha 2L 15-60, 230 V AC 50 Hz, max 45 W, 0,38 A • Two way Control valve Kvs value 2.5 • Temperature limiter of feed temperature • VF-Valve • Check Valve • Isolation valve for the primary circuit • Adjustment valve for primary circuit • Tube Thermometers Can be assembled in both right and left operation directly to the LK Manifold VKF/VKF-i
LK Manifold Shunt VS can be completed with LK Control RSK 241 78 41.
|
Article no.
|
Type
|
Dim WxHxD
|
c/c-conducta prim/sec
|
Conn prim/sek
|
Weight kg
|
Unit
|
| 241 85 12 |
2-2,5 |
360/262x306x164 |
124/213 |
3/4"fm/1"m |
7 |
pcs |
|

|
LK Manifold Shunt CS
Complete pre- manufactured shunt unit with two way control valve. The shunt unit is to be used in systems with main pump in the primary circuit. • Grundfos circulation pump UPS 15-60, 230 V AC 50 Hz, max 70 W, 0,30 A • Two way Control valve Kvs value 2.5 • Temperature limiter of feed temperature • VF-Valve • Check Valve • Isolation valve for the primary circuit • Adjustment valve for primary circuit • Tube Thermometers • Can be assembled in both right and left operation directly to the LK Manifold VKF/VKF-i
LK Manifold Shunt VS can be completed with LK Control RSK 241 78 41.
|
Article no.
|
Type
|
Dim WxHxD
|
c/c pipes
|
Conn prim/sec
|
Weight kg
|
Unit
|
| 241 85 13 |
2-2,5 |
360/262x306x164 |
124/213 |
3/4"fm/1"m |
7,0 |
pcs |
|

|
LK Shunt 2/3- 2,5
Shunt unit to be used for system with main pump in the primary circuit. Complete pre-manufactured unit with: • Grundfos circulation pump UPS 25-60, 230 V AC 50 Hz, max 90 W 0,40 A • Control valve Kvs 2,5 with change over function between 3- and 2-port execution, equipped with hand actuator. • Adjustment valve for the primary circuit. • Check valve. • 2 Thermometers. • Isolation valve for the primary cicuit. • Can be assembled in both right and left operation. • Fixing Bracket
The 3-port valve should be electronically modulated. LK Shunt can be controlled with LK Control RSK 241 78 41.
|
Article no.
|
Type
|
WxHxD
|
c/c-pipe
|
Conn prim/sek
|
Weight kg
|
Unit
|
| 241 80 87 |
2/3-2,5 |
265x525x215 |
150 |
3/4" fm / 1" fm |
9.1 |
pcs |
|

|
LK Shunt 2/3-4,0
Shunt unit to be used for system with main pump in the primary circuit. Complete pre-manufactured unit with: • Circulation pump 230 V AC 50 Hz, max 245 W 1,04 A • Control valve Kvs 4,0 with change over function between 3- and 2-port execution, equipped with hand actuator. • Adjustment valve for the primary circuit. • Check valve. • 2 Thermometers. • Isolation valve for the primary cicuit. • Can be assembled in both right and left operation. • Fixing Bracket
The 3-port valve should be electronically modulated. LK Shunt can be controlled with LK Control RSK 241 78 41.
|
Article no.
|
Type
|
WxHxD
|
c/c-pipe
|
Conn prim/sek
|
Weight kg
|
Unit
|
| 241 78 23 |
2/3-4,0 |
305x850x230 |
150 |
G20inv/G32inv |
10.1 |
pcs
|
|

|
LK FTK Valve
The temperature limit valve is designed for connection to LK Shunt groups. The valve shall be used when a manual regulated shunt unit is connected to a system with constant temperature on the supply feed. The valve shall be mounted on the primary circuit of the shunt unit’s feed pipe. The valve has an adjustable kv value between 0,8 to 2,6.
|
Article no.
|
Dim
|
Length
|
Kv
|
Temp range
|
Unit
|
| 241 74 29 |
3/4" ext. |
145 mm |
0,8-2,6 |
15-50sC |
pcs |
|

|
LK Shunt 2/3-6,3
Shunt unit to be used for system with main pump in the primary circuit. Complete pre-manufactured unit with: • Circulation pump 230 V AC 50 Hz, max 245 W 1,04 A • Control valve Kvs 6,3 with change over function between 3- and 2-port execution, equipped with hand actuator. • Adjustment valve for the primary circuit. • Check valve. • 2 Thermometers. • Isolation valve for the primary cicuit. • Can be assembled in both right and left operation. • Fixing Bracket
The 3-port valve shpuld be electronically modulated. LK Shunt can be controlled with LK Control RSK 241 78 41.
|
Article no.
|
Type
|
WxHxD
|
c/c-pipe
|
Conn prim/sek
|
Weight kg
|
Unit
|
| 241 78 24 |
2/3-6,3 |
330x900x230 |
170 |
G25inv/G40inv |
12.5 |
pcs
|
|

|
LK Shunt UHP-6,3
Shunt unit to be used for system without main pump in the primary circuit. Complete pre-manufactured unit with: • Circulation pump 230 V AC 50 Hz, max 107 W 0,46 A • Control valve Kvs 6,3 with 3-port execution, equipped with hand actuator. • Thermostatic valve for limitation of supply temperature. • 2 Thermometers. • Isolation valve for the primary cicuit. • Can be assembled in both right and left operation directly to the LK Manifold VKF. • Fixing Bracket
The 3-port valve can be manually set or electronically modulated. LK Shunt UHP can be controlled with LK Control RSK 241 78 41.
|
Article no.
|
Type
|
WxHxD
|
c/c-pipes prim/sek
|
Conn prim/sek
|
Weight kg
|
Unit
|
| 241 78 27 |
3-6,3 |
480x530x215 |
145/210 |
G20inv/G25utv |
7.7 |
pcs |
|

|
LK Control RA
Automatic temperature control, consists of electronic controller for weather dependent flow temperature control with program for temperature set back and automatic pump control, valve actuator, weather temperature sensor and flow temperature sensor.
used with:
- LK Manifold Shunt Compact 2-2,6/3,2 and 2-1,2/1,6
|
Article no.
|
Voltage
|
Unit
|
| 241 81 06 |
230 V AC |
pcs
|
|

|
LK Remote Control Unit
Extra over optional choice for LK Control, RSK 241 78 41 and LK Control RA 241 81 06. A remote control unit for temperature and time program. The built in room temperature sensor can also be connected for automatic room temperature control.
|
Article no.
|
use
|
Unit
|
| 241 78 42 |
LK Control/Contol RA |
pcs
|
|

|
LK Fixing Bracket
Wall fixing for LK Manifold Shunt Compact.
|
Article no.
|
Clamp dim
|
Unit
|
| 241 78 13 |
Cu 22 |
pcs |
|

|
LK Control
Automatic temperature control, consists of electronic controller for weather dependent flow temperature control with program for temperature set back and automatic pump control, valve actuator, weather temperature sensor and flow temperature sensor.
Use with: • LK Manifold Shunt VS and CS • LK Shunt 2/3-2,5 • LK Shunt 2/3-4,0 • LK Shunt 2/3-6,3 • LK Shunt UHP-6,3 • LK Shunt UHP 3-10,0
|
Article no.
|
Voltage
|
Unit
|
| 241 78 41 |
230V AC |
pcs |
|
|
|
|