Products and Systems



Underfloor heating
 
Home
About the company
Underfloor Heating Guide
LK Universal Pipe
Products and Systems
Literature
Search
Contact
Site map
Room Control Print
ArticleDescription

LK Room Thermostat NC

Electronic room thermostat with Triac-output and electronic feedback.

• Supply voltage 24 V AC
• Power loss 0,7 W
• Switching power max 15 W
• Max 5 LK Actuator connections

Article no.

Voltage

Unit

241 74 27 24 V pcs

LK Room Thermostat Dti NC

Electronic room thermostat with hidden temperatur setting (for public environments). For technical data see art.no 241 81 09.

Article no.

Voltage

Unit

241 82 49 24V pcs

LK Remote Sensor

Designed for LK Room Thermostat art.no 241 81 09 and 241 81 23 for floor temperature control.

Article no.

Length

Unit

241 75 76 4,0 m pcs

LK Patress

Designed for LK Room Thermostat RSK 241 81 23 and RSK 241 81 09.

Article no.

Colour

Unit

241 74 25 white
pcs

LK Connection Box NC

For electrical connection of LK Room Thermostat 24V AC NC and LK Actuator 24V AC NC. Max 8 control zones with maximum 5 actuators per zone. Note, maximum 12 actuators can be connected in total to the box. The connection box has light emitting diodes LED to indicate the function for each zone. Integrated Transformer 230/24V AC 40VA. Pump connection. The box has an integrated 24-hour valve and pump logic exercise program.

Article no.

Voltage

WxHxD

Unit

241 81 18 230/24V 350x100x60 pcs

LK Actuator 24V AC NC

For individual room/ zone controling together with LK Room Thermostat. The actuater is normally closed (NC).
• Continuous power consumption 2 W
• IP 54

Article no.

Voltage

Unit

241 81 20 24V AC pcs

LK Transformer

Wall mounted transformer.

• 230/24 V AC
• Max power output 60 VA
• IP 44

Article no.

Voltage

Unit

241 77 47 230/24V AC pcs

LK Single Zone Manifold Control NC

For automatic control of one LK Manifold. Automatic 3- way control valve kvs 4,0 incl. electro- thermal actuator 24 V AC. To be completed with LK Room Thermostat and LK Transformer. LK Manifold shall not be used directly on the boiler supply line. The heating system shall be furnished with automatic temperature control equipment, like LK Control, for weather dependent flow temperature control.

Pipe connection to LK Single Zone Manifold Control NC can be done with help of LK Half coupler article nr. 2418164, 2418165 or 2418166.

Article no.

Voltage

Unit

241 81 36 24V pcs

LK Receiver Cq 1 NC

The receiver shall be used with LK Room Thermostat Cq (transmitter 868 Mhz). Max 1 room thermostat can be addressed. Max 8 LK Actuators 24 V AC can be connected. The receiver is powered by 230V AC and with LK Transformer 230/24V AC.

Article no.

Frecq

WxHxD

Unit

241 81 28 868 MHz 71x71x27 pcs

LK Room Thermostat Cq

Wireless room thermostat, controls the room temperature by radio signals, 868 Mhz. The room thermostat shall be used with LK Receiver Cq 1, 4 or 6.

Article no.

Frecq

WxHxD

Colour

Unit

241 78 93 868MHz 75x75x27 White
pcs
241 82 46 868MHz 75x75x27 Silver Grey
pcs

LK Receiver Cq 4 NC

The receiver shall be used with LK Room Thermostat Cq (transmitter 868 Mhz). Max 4 room thermostats can be addressed. Max 4 LK Actuators 24 V AC can be connected to each channel. The receiver is powered by 230V AC and with an additional LK Transformer 230/24V AC.

Article no.

Frecq

WxHxD

Unit

241 81 29 868 MHz 372x57x50 pcs

LK Receiver Cq 6 NC

The receiver shall be used with LK Room Thermostat Cq (transmitter 868 Mhz). Max 6 room thermostats can be addressed. Max 4 LK Actuators 24 V AC can be connected to each channel. The receiver is powered by 230V AC and with an additional LK Transformer 230/24V AC. NOTE: maximum 16 actuators

Article no.

Frecq

WxHxD

Unit

241 81 30 868 MHz 452x57x50 pcs

LK Actuator 230V AC NC

For individual room/ zone controling. Normally closed (NC).

• Continuous power consumption 2 W
• IP 54

Article no.

Voltage

Unit

241 81 21 230 v pcs

LK Actuator 0-10V.

For individual room/ zone controling. Supply votage 24V AC, controlsignal 0-10V DC, normally closed.

• Power consumption 1,5W
• IP 40 
 

Article no.

Voltage

Unit

241 81 22 0-10V/24V DC pcs

LK Electronic Thermostat TR 26

LK Electronic Thermostat, used in special environments such as wash halls, animal stables etc. The Thermostats is completed with floor or room temperature sensor (LK Cable Sensor FK133/4 or LK Room Temperature Sensor FS 103). Up to 10 LK Actuator 24V AC or 8 LK Single Zone Manifold Control can be controlled by the thermostat. The operating voltage is 230V AC and the change over contact is connected to 24V AC to the actuators by an LK Transformer 230/24V AC 60VA. The thermostat is made for DIN rail mounting and preferably placed in LK DIN Box (IP 55).

Article no.

Operating voltage

1 change over, voltage free

Temp.
range

Protection
class

Unit

241 81 48 230 V AC 24/230 V AC 0-60°C IP21 pcs

LK Cable Sensor FK 133/4

LK Cable Sensor, used with LK Electronic Thermostat TR26 when controlling the floor temperature.

Article no.

Length

Unit

241 81 49 4 m pcs

LK Room Temperature Sensor FS 103

LK Room Temperature Sensor FS103, used with LK Electronic Thermostat TR26 when controlling the room temperature.

Article no.

Protection Class

WxHxD

Unit

241 81 74 IP55 78x88x41,5 pcs

LK DIN Box

LK Box with DIN rail. Up to 2 LK Electronic Thermostat TR26 can be mounted.

Article no.

Protection Class

WxHxD

Unit

241 81 75 IP55 105x170x98 pcs
 
Română (România)English (United Kingdom)

Search site

We have 36 guests online